<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-16 00-48-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 4/5, 46 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 31 kHz 6749 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,2 dBr 1,46 dBr 2,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"New Seasons Ensemble "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 31 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/16 0.47.22 Total samples: 6749 Equivalent time: 0:05:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: 2,7 dBr MIN: -1,2 dBr AVE: 1,46 dBr % above 12,2 dBr: 0,0 Last value: 2,7 dBr (2026/01/16 0.47.21) 00.34 00.36 00.38 00.40 00.42 00.44 00.46 -2 -1 0 1 2 3 Pm [dBr]